# Case Study: Radon Mitigation in Chesterfield With an Active Sump Pit

- **URL:** https://airsenseenvironmental.com/case-studies/radon-mitigation-active-sump-pit/
- **Published:** 2026-10-06

Skip to content Radon Mitigation Services ▾ Radon Testing Commercial Radon Mitigation Commercial Radon Testing Indoor Air Quality Crawl Space Encapsulation Service Area Resources FAQ Blog Podcast Reviews & Projects About Us Contact 314-664-9807 Free Estimate Radon Mitigation Services Radon Testing Commercial Radon Mitigation Commercial Radon Testing Indoor Air Quality Crawl Space Encapsulation Company Service Area Resources FAQ Blog Podcast Reviews & Projects Case Studies Media Room About Us Contact Call 314-664-9807 Case Studies · Chesterfield, Missouri Radon Mitigation in Chesterfield With an Active Sump Pit and a High Water Table Customer Story Sealed Sump With Viewing Window Garage & Attic Routing A Chesterfield homeowner with a very active sump pit and a higher-than-usual water table needed a radon system that sealed the pit without losing access to it. Air Sense Environmental installed a one-suction-point sub-slab system, sealed the pit under a custom cover with a viewing window, and routed the vent through the garage and attic. The homeowner’s EcoQube monitor read 4–5+ pCi/L before mitigation. After installation, its 72-hour average settled below 1.0 pCi/L. Call 314-664-9807 Get a Free In-Home Estimate Homeowner’s Monitor Readings Before mitigation4–5+ pCi/L 72-hour average after< 1.0 pCi/L Readings from the homeowner’s EcoQube consumer monitor. The EPA action level is 4.0 pCi/L. At a Glance Project Summary Location: Chesterfield, St. Louis County, Missouri Installed: September 2026 Challenge: very active sump system and a higher-than-usual water table System: sub-slab depressurization with one suction point; sump pit sealed under a custom cover with a viewing window Routing: vent through the garage and attic, with the fan in the attic Installation time: under four hours Scheduling: installed less than two weeks after the first call Result: homeowner’s monitor went from 4–5+ pCi/L to a 72-hour average below 1.0 pCi/L The Situation A Sump Pit That Had to Stay Accessible Andrew Newbold had been tracking radon in his Chesterfield home with an EcoQube monitor, which showed levels in the 4–5+ pCi/L range. The EPA recommends fixing a home at or above 4.0 pCi/L. His sump pump runs often because the water table around the house is high. An unsealed sump pit lets soil gas into the house and leaks the vacuum a radon system creates under the slab. Andrew also needed to keep watching the pump and check valves. Before the appointment, he sent Jake his EcoQube data and photos of possible installation locations. Jake replied with feedback and sent photos of a recent garage installation so Andrew could picture one of the routing options. What We Did One Suction Point and a Sealed, Accessible Sump On installation day, Jake Lusby, owner of Air Sense Environmental, worked through the routing options with Andrew and explained each step as the system went in. The system uses a single suction point under the slab. Before sealing the pit, Jake had Andrew hold his hand near the opening to feel the suction under the slab. Strong negative pressure there shows the system is pulling air from beneath the house, a sign of good sub-slab communication. The sump and check valves were laid out in a way a standard cover would not fit. Jake built a custom cover that seals the pit airtight but can still be opened, and added a viewing window so Andrew can watch the pump without breaking the seal. The vent runs up the garage wall and through the attic, with the fan in the attic where it is protected from the weather. Jake and his son finished the installation in under four hours and cleaned up the work area. The finished vent run in Andrew’s garage, with the U-tube manometer and installation tag on the pipe. Photo: Andrew Newbold, shared with permission. The Result From 4–5+ pCi/L to Below 1.0 Andrew’s EcoQube readings began falling within hours of the system being turned on and read 0.4 pCi/L the next morning. Over the full 72-hour period, his average settled below 1.0 pCi/L. “My EcoQube was showing radon levels in the 4–5+ pCi/L range before mitigation. Within hours of the system being turned on, the readings began steadily falling, and by the next morning my EcoQube was reading 0.4 pCi/L.” “Before sealing it, Jake actually had me put my hand near the opening so I could feel the strong negative pressure being created beneath the slab. That was an immediate indication that the system had good communication beneath the house and gave me a lot of confidence in how well the mitigation would perform.” “Being able to continue seeing what is happening inside my sump without compromising the radon seal is extremely helpful for my situation.” — Andrew Newbold, Chesterfield, MO · Google review, September 15, 2026 These readings come from a consumer monitor. Radon levels change from hour to hour and season to season, so Air Sense Environmental recommends a follow-up radon test after mitigation to confirm the level. Takeaways What This Project Shows Seal the sump pit. An open pit is a radon entry point and leaks the vacuum under the slab. See sump pump radon mitigation. Sealed does not have to mean inaccessible. A cover with a viewing window keeps the pump visible in homes where it runs often. Good sub-slab communication matters. One suction point was enough here because suction reached across the slab. See how sub-slab depressurization works. Routing is a design decision. Running the vent through the garage and attic kept the fan protected and the exterior clean. Monitor data helps planning. Sharing readings and photos before the visit let the routing options be discussed ahead of time. Confirm with a follow-up test. A post-mitigation radon test confirms what a monitor shows. Related Learn More Radon mitigation in Greater St. Louis Reading your radon manometer More case studies Reviews and projects Your Home Tricky sump, crawl space or routing? Send us your test results and a few photos, and we will talk through the options before we visit. Call 314-664-9807 5237 Old Alton Edwardsville Rd Edwardsville, IL 62025 314-664-9807 · Open 24 hours Jacob Lusby · IEMA RNM20232346 Services Radon Mitigation Radon Testing Commercial Radon Commercial Radon Testing Radon Fan Replacement Sub-Slab Depressurization Indoor Air Quality Crawl Space Encapsulation Company About Us Service Area Reviews & Projects Case Studies FAQ Blog Podcast Resources Media Room Contact © 2026 Air Sense Environmental. All rights reserved. Radon Mitigation & Testing · St. Louis, MO & Metro East, IL
